Rational Service 34 — Bus Signal Problem

Service 34 means the main board is not talking properly to one of the parts on its communication bus.

Got a code on the screen? Send us a photo. Most of the time it tells us what to bring.

Send a photo of the screen
CodePart
34.1Fan motor, top
34.2Fan motor, bottom
34.4Ignition module, top
34.8Ignition module, bottom

Numbers combine, so 34.12 means both ignition modules.

What to do

The first check is the bus cable and its plugs, which can come loose or get damaged. If the wiring is sound, the motor controller or the ignition module itself has failed.

Call (424) 424-2302

with the full number on the screen.

Tell us what the oven is doing

(424) 424-2302

Call, or send the form with a photo of the screen. We reply within working hours, Monday to Saturday.